Thermo TVA-1000B PID/FID Kit 115V Charger

The Thermo TVA-1000B PID/FID Kit 115V Charger is a comprehensive system designed for the detection and measurement of volatile organic compounds (VOCs) in various industrial, environmental, and laboratory applications. This kit includes a sophisticated combination of two types of detectors: the Photoionization Detector (PID) and the Flame Ionization Detector (FID), allowing for versatile, high-precision analysis of gases.

Key Features:

  1. PID Detector (Photoionization Detector):

    • The PID detector is highly sensitive to a wide range of VOCs, offering rapid detection of compounds at low concentration levels. It is particularly effective for monitoring toxic gases such as solvents, hydrocarbons, and industrial chemicals.
    • This makes it ideal for applications in areas such as air quality monitoring, industrial hygiene, and environmental testing.
    • It uses UV light to ionize gas molecules, generating ions that can be measured by the detector, providing a high level of sensitivity.
  2. FID Detector (Flame Ionization Detector):

    • The FID detector provides enhanced sensitivity and precision in detecting hydrocarbons, including methane and heavier gases. It is often used in petrochemical, environmental, and pharmaceutical industries for trace gas analysis.
    • The FID works by measuring the ions formed when gases are burned in a hydrogen flame, offering a robust method for detecting organic compounds.
  3. 115V Charger:

    • The Thermo TVA-1000B kit comes with a 115V charger, ensuring that the portable system can be recharged efficiently when needed, making it convenient for field operations or mobile environments.
    • The charger is designed for ease of use and to ensure that the equipment maintains its operational capabilities over extended periods of use.
  4. Portability & Flexibility:

    • The TVA-1000B system is designed to be lightweight and portable, allowing for both indoor and outdoor usage in diverse environments. It is perfect for mobile applications such as emergency response teams, environmental monitoring stations, and industrial plant inspections.
    • The integrated kit is user-friendly, featuring simple interface controls, making it easy to set up and operate, even for non-experts.
  5. Applications:

    • Industrial Monitoring: Detect and quantify volatile organic compounds (VOCs) and gases in manufacturing, chemical, and processing plants.
    • Environmental Testing: Monitor air quality and pollutant levels in urban or rural settings, ensuring compliance with environmental regulations.
    • Research & Development: Used in laboratories for studying the behavior of volatile compounds, chemical reactions, and more.
    • Safety & Hazardous Materials Management: Ideal for safety teams to quickly assess hazardous exposure levels in industrial or commercial settings.
  6. Calibration and Maintenance:

    • The Thermo TVA-1000B is designed to be calibrated and maintained with minimal effort. Routine calibration ensures that the system continues to provide accurate readings, while the built-in self-diagnostic features help troubleshoot any potential issues.

 

Specification

General Specifications:

  • Model: Thermo TVA-1000B PID/FID Kit
  • Power Supply: 115V AC Charger
  • Weight: Approximately 3.5 kg (7.7 lbs)
  • Dimensions: Compact, portable design for easy transport
  • Operating Temperature: Typically ranges from -10°C to +50°C (14°F to 122°F)
  • Humidity Range: 0-95% non-condensing
  • Battery Type: Rechargeable lithium-ion battery (long life and reliable performance)
  • Battery Life: Up to 10 hours on a full charge (depending on usage)

PID Detector (Photoionization Detector):

  • Detection Range: Typically from 0.1 ppb (parts per billion) to 10,000 ppm (parts per million) depending on the gas
  • Ionization Energy: 10.6 eV (standard)
  • Detector Type: Photoionization using a UV lamp
  • Response Time: < 3 seconds for most gases
  • Sensitivity: High sensitivity to VOCs and low molecular weight hydrocarbons
  • Compounds Detected: Volatile organic compounds (VOCs), solvents, aromatic hydrocarbons, and others
  • Gas Identification: Does not provide gas-specific identification, but can be calibrated for a specific gas or group of gases
  • Tuning: Adjustable sensitivity depending on the compound of interest

FID Detector (Flame Ionization Detector):

  • Detection Range: 1 ppm to 100,000 ppm
  • Fuel Gas: Hydrogen (H2) required for the FID flame
  • Carrier Gas: Typically Nitrogen (N2) or Zero Air
  • Ionization Method: Flame ionization by burning gases in a hydrogen flame
  • Response Time: Typically < 1 second
  • Sensitivity: Sensitive to hydrocarbons, including methane, ethane, and heavier organic compounds
  • Applications: Ideal for detecting and quantifying hydrocarbons and organic compounds

Charger and Battery:

  • Input Voltage: 115V AC (Standard US power supply)
  • Charging Time: Typically 4-6 hours to fully charge
  • Battery Life: Approximately 8-10 hours on a single charge (dependent on operational use)
  • Charger Type: 115V AC wall charger with safety features such as overcharge protection and short-circuit prevention

Display and Interface:

  • Display Type: Digital LCD or LED display for clear readout of measurements and system status
  • Interface: User-friendly interface with easy-to-navigate controls
  • Alarm Functions: Visual and audible alarms for detection of high concentration levels of VOCs or other hazardous gases
  • Data Logging: Optional data logging capabilities (depending on the specific model configuration)

Environmental and Safety Standards:

  • CE Compliant: The system complies with CE standards for electronic equipment and safety
  • IP Rating: IP54 or higher (dust and water-resistant, suitable for fieldwork and industrial environments)
  • Safety Features: Overload protection, low battery indication, calibration reminders, and fault detection for safe operation

Accessories Included:

  • 115V Charger
  • Protective Carrying Case: For safe storage and transportation
  • Instruction Manual: For setup, calibration, and operation
  • Calibration Tools: Calibration gases or kits may be sold separately depending on the specific needs of the user

Applications:

  • Environmental Monitoring: Detection of VOCs and pollutants in the air
  • Industrial Hygiene: Workplace safety for monitoring exposure to harmful gases
  • Emergency Response: Quickly assess air quality and identify hazardous gas levels in emergency situations
  • Laboratory Analysis: Suitable for use in research and development labs where gas composition analysis is needed
  • Petrochemical and Pharmaceutical Industries: For monitoring hydrocarbon levels in industrial and production environments

Find Similar Products by Category