Thermo Scientific Miran Sapphire XL-205B Ambient Air Analyzer
The Thermo Scientific MIRAN SapphIRe XL-205B Ambient Air Analyzer is a portable, lightweight infrared instrument designed for precise monitoring of ambient air in various environments.
Utilizing a single-beam infrared spectrophotometer, it can detect and quantify a wide range of organic and inorganic gases, making it a versatile tool for professionals in industrial hygiene, emergency response, indoor air quality assessments, hospital gas monitoring, fume hood testing, and leak detection.
Key Features:
Exclusive Wavelength Generator Filter Design: Allows accurate and rapid wavelength selection, enhancing measurement precision.
Extensive Gas Library: The XL model comes pre-configured with a library of 121 individual gas compounds, providing flexibility in various applications.
High Sensitivity: Capable of sub-ppm (parts per million) detection, ensuring the identification of low-concentration gases.
Versatility and Upgradability: The analyzer is adaptable to evolving needs and can be upgraded with additional features or gas libraries as required.
Portability: Weighing approximately 15 pounds, it is designed for easy transport and field use, with an internal rechargeable battery providing up to four hours of continuous operation.
Applications:
Industrial Hygiene Monitoring: Assists in evaluating workplace environments for hazardous gas exposures.
Emergency Response Analysis: Provides rapid identification of unknown gases during emergency situations.
Indoor Air Quality Studies: Assesses air quality in residential, commercial, and institutional settings.
Hospital Gas Monitoring: Monitors medical air and anesthetic gases to ensure compliance with health standards.
Fume Hood and Tracer Gas Testing: Evaluates the performance of ventilation systems and identifies leaks.
Leak Detection: Identifies and quantifies gas leaks in various industrial processes.
Included Accessories:
The MIRAN SapphIRe XL-205B typically includes the following accessories:
Two batteries
Two-station charger
Power cord
Chassis cable
Battery pack
Interface cable
Sampling wand assembly
Particulate filter
Zero gas filter
Printer cable
Serial communications cable
Pathlength changer tool
Unit setup software
Computer interface program
Carrying case
Operating manual
Specifications:
Measurement Specifications:
Measurement Range: Compound-dependent; refer to Appendix H in the instruction manual for specific ranges.
Absorbance Range: 0.000 to 1.2 absorbance units (practical upper limit).
Measurable Gases: Factory-calibrated for 120 single gases; capable of storing up to 10 single-gas and 10 multi-gas applications.
Wavelength Selection: Features seven fixed bandpass filters and a continuously variable linear filter covering 7.7 to 14.1 microns.
Response Time: 18 seconds to reach 90% of the final reading.
Analysis Time: Post-purge, typical times are 20 seconds for a single wavelength, 50 seconds for five wavelengths, and 165 seconds for a spectral scan.
Pump Flow Rate: Approximately 14 liters per minute with sampling wand and particulate filter.
Power Specifications:
Battery Type: Internal, rechargeable, sealed, intrinsically safe Nickel-Cadmium (NiCd) battery pack with a nominal voltage of 7.2V and a capacity of 5.7 Ah.
Operating Time: Up to four hours of continuous operation at 23°C.
Recharge Time: Approximately four hours after complete discharge if the analyzer is off; about two hours for each hour of discharge from full capacity if the analyzer is off.
Additional Features:
Output Options: Digital readout of concentration in ppb, ppm, %, mg/m³, or absorbance units (AU); connections for analog output, relay contacts, parallel port (printer), and serial communication (RS232).